1. Description -------------- The Landis+Gyr .MAP110 Service Tool is designed to read and set device data of Landis+Gyr meters via the dlms and the IEC protocol. Additionally, various analysis and diagnostic functions are available. 2. Most recent changes, enhancements and bug fixes -------------------------------------------------- Changes to release 5.9.14 (2018-04-19) - New devices and firmware releases: - E450 series: ZCXi100Q S4 with firmware release V91.11.11 - E450 series: ZMXi300Q S4 with firmware release V93.11.11 - E460 series: MCA100 with firmware release V75.01.03 - E65C series: CU-L52 with firmware D81 - Communication: dlms gateway protocol fully supported over all transport layers (including extended communication tracing). - Command tree: New feature in toolbar and context menu added to open stored data of a command. The feature is active as soon as a command in the tree is selected. Please note that this is available for selected commands only, e.g. Vector Diagram, Wireless M-Bus Devices, Extended Time of Use (TOU). - New GUI for the following commands: - GSM installation support (including print support) - Vector diagram (including print support) - Wireless M-Bus devices (including print support) - Read and write of optical and electrical interfaces - Read and write of power factor monitor thresholds - Read and write of demand monitor thresholds - Read and write of power quality functions - Read communication statistics (Excel export removed) - Write single reset settings - Write smart street lighting - Consumer information interface: Activate/deactivate CII client now with immediate effect (no manual restart required). - E850 series: Primary data adaptation fixed (arithmetic overflow removed). - E850 series: Billing values and instantaneous values of E880 (firmware H80) restricted to primary data only (no secondary values and no transformer ratios anymore). - E850 series: Primary data adaptation of E880 (firmware H80) restricted to primary data only (no secondary values and no transformer ratios anymore). - E65C series: Assignment of time windows fixed for CU-Ex in case of fixed IP address. - E65C series: Adaptation of all read and write commands of the extended communication settings to be more generic, i.e. GSM/GPRS replaced by mobile data network. - E350 series: Read and write of electrical interface settings added for firmware M22. Changes to release 5.8.10 (2017-11-30) - New devices and firmware releases: - E35C series: AD-xU with firmware release V54.10.10 - E460 series: MCA100 with firmware release V75.01.03* - Profile readout: Enhanced support for negative values and values with large negative scalers. - TOU: ID numbers are not filled with zeros anymore (valid for E35C, E460, E570, E450 S3/S4). - E650/S650 series: Latest changes in primary data adaptation for B40. - E650/S650 series: Display format of losses reduced to be in line with MAP120 (firmware B40 only). - E650/S650 series: Power factor threshold fixed (firmware B40 only). - E65C series: GSM Pin code can bet set again (firmware D81 only). - E65C series: Initial transmission speed can be changed again in CU-E22 in case of automatic protocol detection. - E460 series: New GUI for disconnector arbitrator. - E460 series: New command to unpair the P160 customer interface unit. Changes to release 5.7.16 (2017-10-10) - E650/S650 series: Various corrections in primary data adaptation. Changes to release 5.7.12 (2017-09-11) - Communication: Improved handling of access errors in various commands - New devices and firmware releases: - E650/S650 series: ZxD300/400 S4 and SxA400/500 S4 with firmware release B40. - E450 series: ZCXi100Q S4 with firmware release V91.10.10 - E450 series: ZMXi300Q S4 with firmware release V93.10.10 - Complete revision of firmware update of E450, E460, E570 series as well as E35C V4.x modules. Former command split into 3 commands: - Firmware Update Metering Application - Firmware Update M-Bus Driver - Firmware Update PLC Modem Driver - Resume feature added, i.e. a previously initiated firmware update can be continued. - Multi utility: VIF and DIF values are shown in hexadecimal format only. - Billing period reset settings: GUI and text adapted to better support high resolution displays. - E65C series: Empty dial in number supported again in write command of GPRS settings. - E850 series: Vector diagram shows primary data for E880 devices (firmware H80). Changes to release 5.6.22 (2017-06-26) - New devices and firmware releases: - E460 series: MMA300 with firmware release V76.01.00 - E460 series: MCA100 with firmware release V75.01.02 - Communication: Handling of dlms buffer size 0 fixed in the write command of the clock. - E65C series: TCP/IP settings can be modified again for all Px/Ux devices. - E65C series: Selection of IP address modes fixed for P2x devices. Changes to release 5.6.18 (2017-06-01) - Communication settings: New version (V14) of the communication settings introduced. Former settings are converted at the first start-up of the tool. - Communication settings: Various modifications and extensions to support future devices: - New access level L (Access Administrator) introduced with own key set for authentication and encryption. - Authentication mechanism 6 (SHA-256) and message security added to access levels 1,2,G and L. - Password length extended to be in the range of 8..16 bytes. - Device security settings split into 2 tabs: 'Access Level' and 'Keys'. - Device settings extended to support up to 3 key sets (global, local and administrator). - Device settings extended with manufacturer serial number (optional, no features assigned). - User manual and tool help updated. - Communication settings: Address book entry can be deleted. - Communication settings: In the communication channel settings the order of the interface type and the interface selection has been reverted. The list of interfaces is filtered by the interface type now. - Communication settings: Problems fixed while opening communication settings dialogue after complete new installation. - Communication: Network connections via URL supported again. - Communication: Modem error handling further improved. - Communication: Destination IP address shown in status bar. - Communication: Communication session remains active as long as an input dialogue is open. - New devices and firmware releases: - E450 series: ZCXi100P S2 with firmware release V43.05.00 - E450 series: ZMXi300P S2 with firmware release V48.05.00 - E450 series: ZMXi300P S3 with firmware release V65.04.00, V65.03.00* - E460 series: MMA300 with firmware release V76.01.00* - Command tree: Folder 'In Home Display' folder renamed to 'Consumer Information Interface' and functionality extended. - Command tree: Folder 'Password an Keys' renamed to 'Security' - Command tree: Activate new firmware commands moved to firmware update folder. - Result window: Overview picture extended with new devices. - Relays: Complete new GUI with extended support for relay switching independent of control mode. - Relays: Commands extended to support additional devices (E35C, E450 S4, E460). - E65C series: All commands to change the communication settings replaced to better support high resolution displays. - E450 series: Additional commands to change the message security policies. Changes to release 5.5.12 (2017-01-18) - Communication settings: All serial interfaces supported after first time installation. - New devices and firmware releases: - E450 series: ZCXi100Q S4 with firmware release V91.06.03 - E450 series: ZMXi300Q S4 with firmware release V93.06.03 Changes to release 5.5.08 (2016-12-16) - Communication settings: Use of password protected utility key for key import supported. - Reset alarm registers: Modified for E570 with firmware V82.03.03, E35C with firmware V54.01 and E450 S4. Changes to release 5.5.06 (2016-11-04) - Communication settings: New version (V13) of the communication settings introduced. Former settings are converted once at the first start-up of .MAP110 5.5. - Communication settings: TCP and UDP supported in the network layer. Choice added to the physical layer tab in the communication channel settings. - Communication: 'TCP' and 'UDP' supported in communication status bar. - Options: GUI of colour selection of inactive commands modified. - Display: Various enhancements to better support high resolution monitors: New message box, enhanced icon handling (not finished yet). - New devices and firmware releases: - E570 series: ZxYi400G with firmware release V82.03.03* - Multi utility: Combined wireless M-Bus operation mode 'C/T Mode' changed to 'C Mode'. - User manual and tool help updated. Changes to release 5.4.20 (2016-08-19) - New devices and firmware releases: - E460 series: MCA100 with firmware release V75.01.02* - Profile readout: Additional hint is shown in case the profile values might be shown in raw format because of insufficient access rights. - Multi utility: In the list of wireless devices the M-Bus device ID is shown correctly. - Multi utility: M-Bus status is encoded in a tool tip while reading M-Bus registers and profiles. - Multi utility: Additional units are shown in the multi utility register readout. - Multi utility: Optional key wrapping possibility added in the transfer M-Bus key command. - E35C series: Changes to the GPRS and the PPP setup are getting active immediately after execution of the command. - E65C series: Length of GPRS user name and password extended. - E450 S4 series: Multi utility configuration of channel 2 fixed. Changes to release 5.4.16 (2016-05-18) - Operating System: Microsoft .NET framework 4.6.1 or later is required to operate Landis+Gyr .MAP110 5.4. - Communication settings: Device names containing unsupported special characters (?,',&,>,<) don't create an exception anymore. - Version information: New GUI including license information. - Licensing: Further use of deprecated license types (e.g. Sales Support) supported again. - New devices and firmware releases: - E35C series: AD-xU with firmware release V54.01.01 - E450 series: ZCXi100Q S4 with firmware release V91.05.02 - E450 series: ZMXi300Q S4 with firmware release V93.05.02 - E460 series: MCA100 with firmware release V75.01.01* - Multi utility: Existing commands modified and additional commands added to support wireless M-Bus devices. - Multi utility: List of predefined devices extended with wireless standard and wireless communication mode. Additional rules added to check them against wireless M-Bus settings. - Multi utility: Unused and wrongly defined devices removed from list of predefined devices. - Multi utility: Write commands partly moved to execute commands. - Multi utility: Encoding of M-Bus identification number changed to BCD. - Multi utility: Write M-Bus address command activates new parameters immediately. - Firmware update: Error handling in case of interruptions improved. Changes to release 5.3.16 (2016-01-21) - New devices and firmware releases: - E450 series: ZCXi100Q S4 with firmware release V91.04.01 - E450 series: ZxXi300Q S4 with firmware release V93.04.01 Changes to release 5.3.12 (2015-11-16) - Operating Systems: Windows 10 supported. - Setup: .MAP110 is directly located in the 'Landis+Gyr' program group (no subgroup anymore, choice removed from setup). - Setup: Uninstall removed from start menu. Please use the control panel to uninstall the tool. - Communication settings: Block transfer for write, set and action can be enabled and disabled in the dlms application layer settings. - Data export to .MAP100: Export of data done in .MAP100 version 3.0 format. - New devices and firmware releases: - E35C series: AD-xU with firmware release V54.01.00 - E350 series: ZCF100 with firmware release M59 - E350 series: ZMF100 with firmware release M29 - New commands (not supported for all devices): - Write GPRS modem setup (APN, pin code). - Write PPP setup (PPP username and password). - ID numbers: Range extended to all printable characters (E450 and E570 series only). - Profiles: Number of profile entries added in range selector. - Firmware update: COSEM logical device name added to the status bar at the beginning of the wizard. - Firmware update: The extended firmware version is shown everywhere in the wizard. - Firmware update: The selection of the firmware type is restricted depending on the device series. - Firmware update: Update of wireless M-Bus drivers supported. After the activation of an M-Bus driver the M-Bus driver firmware version is shown in the check window. - Firmware update: Error message added in case of communication problems during startup of the wizard. - Relay and disconnector: The current state after reading is only shown in the command log. - Relay and disconnector: After writing the former state is not shown anymore. - E650 series: In primary data adaptation losses are adapted during editing to match the capabilities of the device if necessary. - E570 series: New primary data is immediately activated. Changes to release 5.2.08 (2015-08-24) - IEC readout billing data: Excel export supported again. - E570 series: Reset alarm registers affects all 3 registers. - E570 series: Reading of multi utility registers extended to show 8 registers per M-Bus channel. - E570 series: Extended M-Bus configuration parameters are read and written completely. Changes to release 5.2.06 (2015-06-30) - Communication settings: No limitation in the number of devices anymore. - Communication settings: In the dlms application layer settings of a communication channel the default list of single request firmware releases has been extended and the wildcard '*' is supported. This change is only visible in case of a first time installation. - Command log: In the status bar for all devices the type designation is shown instead of the config ID. - Generic IEC commands: New command to change the output pulse constant as well as the pulse width added. - New devices and firmware releases: - E350 series: ZCF100 with firmware release M57 - E350 series: ZMF100 with firmware release M28 - E450 series: ZCXi100Q S4 with firmware release V91.00.00 - E450 series: ZxXi300Q S4 with firmware release V93.00.00 - E570 series: ZxYi400P with firmware release V81.02.02 - E570 series: ZxYi400G with firmware release V82.02.02 - Firmware update: Immediate activation supported again in all cases. - In Home Display E450: New input field to calculate the RF address from the serial number added. - E230 series: Saving of a display list to a file supported again. - E230 series: Wrong decoding of status register removed from event log readout. - E650 series: After writing the time of use the resulting table is displayed (firmware B31 and up). Changes to release 5.1.06 (2015-03-02) - Communication settings: Entry dialogue of passwords fully visible if the font size of Windows is larger than 100%. - Command tree: Designations of several device series adapted. - New devices and firmware releases: - E650 series: ZxD300/400 with firmware release B33 - E550 series: ZxG300/400 with firmware release P08 and P09 - E450 series: ZCX100P with firmware release V01.02.14 - E450 series: ZMX300P with firmware release V03.02.14 - E450 series: ZCXi100P with firmware releases V43.04.00 - E450 series: ZMXi300P with firmware releases V48.04.00 - E450 series: ZMXi300P with firmware releases V65.02.00 - Firmware update: Various enhancements to support new devices with firmware separation. - E650 series: Primary data adaptation with a ratio larger than 6553:1 supported for meters with a nominal current of 0.3 A. - E450 series: Command "Set to 'PLC NEW' state" supported for all PLC variants. - E450 series: Command to read status of M-Bus device added. - E450 series: Writing of extended M-Bus configuration fixed (register unit written as well). - E350 series: Drop down list to select the output pulse value modified. - E35C V3.x series: COSEM logical device name shown correctly again. Changes to release 5.0.26 (2014-12-04) - User manual and help file have been adapted and extended to release 5.0. - Communication settings: Major performance improvements in saving the communication settings. Mainly visible when a large number of devices has been defined. - Communication settings: After upgrading the communication settings from a former version a corresponding message is shown once. Changes to release 5.0.24 (2014-10-24) Major changes in the area of the communication features have been done to support ciphered communication as defined in dlms/COSEM Green Book 7. - This includes enhanced access security (new authentication methods) as well as message security. - The supported range of passwords and keys has been extended: Not only visible strings but also hexadecimal values can be entered. - The security material (keys and passwords) is individually managed per device but not only globally. Therefore the device settings have been extended by the necessary security settings. - An additional storage policy for keys and passwords has been introduced to support time limited storage. - The security material (keys and passwords) and the storage policy are stored in encrypted format per Windows user. Therefore it is not possible to share keys and passwords between different Windows users on the same PC. - Setup: diCryptoSys.dll needed for ciphered communication is kept in case of update or repair on x64 systems. - Tool options: Settings distributed on 3 tabs and storage policy for keys and passwords added - Tool options: Any change in the storage policy leads to a deletion of all keys and passwords. - Tool options: Delay between two commands enhanced to 99'999 seconds. - Communication: Application not blocked anymore if the network interface is not responding. - Communication settings: New version (V12) of the communication settings introduced. Former settings are converted at the first start-up of the tool. - Communication settings: Status bar added to the communication settings overview. OK button removed. - Communication settings: The size and the position of the communication settings dialogue is kept in the user settings. - Communication settings: The access level settings have been moved to an own TAB in the communication settings to be in line with the other settings. The modification of access level settings is done in a dialogue box. - Communication settings: 3 completely independent user defined access levels are supported. - Communication settings: The access levels have been extended to support high level access security (HLS) with mechanism 3=MD5, 4=SHA-1 and 5=GMAC as well as message security. - Communication settings: The access levels have been extended by an optional user ID. - Communication settings: Password and key range extended: Not only visible strings but also hexadecimal values can be entered. - Communication settings: The device settings are distributed on 3 tabs. - Communication settings: The logical device in the device settings has been extended (user defined value in the range of 0..255 can be set). - Communication settings: The device settings have been extend to support a device specific management of access levels. This mainly applies to the definition of passwords and keys. - Communication settings: Key import from file added. - Communication settings: Remote addresses in a link are not deleted automatically anymore if in the related channel the interface is switched from a modem or a network adapter to a serial COM port. - Communication settings: The address book has been extended to not only support numeric IP addresses but any web address (URL). - Readout of billing values: Designation of energy registers extended by type (active/reactive/apparent energy) and direction (import/export). - Profiles: Major performance enhancements in the handling of large profile buffers. - Extended time of use: Various changes in the GUI and enhanced error handling. - Extended configuration M-Bus devices: GUI modified to support more M-Bus registers. - Disconnectors: Control mode added when showing the current state. - In home display E450: New GUI and enhanced error handling. - Write time of use (TOU): While creating a new TOU table the first day ID is labelled 1 instead of 0. - Write passwords: New GUI and enhanced range: Not only visible strings but also hexadecimal values can be entered. - Communication log: Decoding of the info field in various HDLC frames fixed. - New devices and firmware releases: - E65C series: CU-U5x with firmware release D81 - E450 series: ZMX300G with firmware release V07.02.02 - E450 series: ZMX300P with firmware releases V09.00.01 and V09.00.00 - E650 series: Primary data adaptation extended by demand monitoring. - E650 series: Capture period change supported (firmware B32 only). - E650 series: dlms response delay added to the parameters of the electrical interfaces (firmware B32 an up). - E450 series: Writing of access level 2 password added for ZxXi100/300 devices. - E65C series: Reading and writing of modem initialisation strings available as own commands but not as part of the general modem settings anymore. - E65C series: Signal strength profile reading command moved into 'Profile' folder. - E65C series: IP address after readout shown correctly for all values. - E65C series: IPT password can be changed. - E65C series: Dial in number to GPRS network can be enabled but not only changed. - Firmware update E450 and E35C V4.x: Generation of image files separated (own step in wizard) and modified: Generation of an image file is independent of the binary file name. - Firmware update E35C V3.x: Download process has been adapted to better support upgrade via GPRS networks. - Firmware update E35C V3.x: No error message after the successful activation of the new firmware anymore. - dlms emergency readout: supported for E35C communication module AD-xU with firmware V56.00.00. Changes to release 4.9.10 (2014-04-02) - Data export to MAP100 supported again. - Generic dlms commands supported again. - New devices and firmware releases: - Communication module AD-xU with firmware release V56.00.00 - E230 series: TOU table download from file fully supported (now access error anymore). - E230 series: Additional entry to detect terminal cover tampering added to readout list. - E850 series: In case of primary data adaptation the output pulse value of an energy direction contact can be edited. Changes to release 4.8.10 (2013-12-13) - Operating systems: Windows 8 supported. - Setup: Main version number (4.8) added to all program links in the Windows start menu to allow an unambiguous identification of the program in case of multiple installations. - Setup: Update component (dMAPUPdate) removed from the setup since its functionality is fully integrated into the .MAP110 application. - Communication settings: Character set of all passwords extended to upper and lower case letters, i.e. the range supported is: '0'..'9', 'A'..'Z' and 'a'..'z'. - Communication: Blocking of modem after some error states removed. - Generic IEC commands: Supported again for completely unknown firmware releases. - Result window: Various enhancements, e.g. the title of the executed command is shown in the top right corner - Profiles: Display and Excel Export independent of regional settings again. - DIP table: Legend added again. - DIP table: Meter serial number and reading time added. Also present when loading data from file. - GSM installation tree: Signal strength of neighbour cells correctly shown again. - Primary data adaptation: also supported for E650 series (firmware B31 and B32 only). - New devices and firmware releases: - E450 series: ZFXi300P with firmware release V68.02.01 - E65C series: CU-P4 with firmware release D72 - E650 series: Phone number character set for alert SMS extended. - E450 series: Readout of M-Bus identification numbers extended by an additional number (serial number of M-Bus setup). - all E450 IDIS devices and ZMX300G: M-Bus Registers extended by DIFE and DIFEE. - CU-Px: Visualisation of CU modem settings adapted and improved. - E470: Not generally supported anymore, dedicated license needed. Changes to release 4.7.20 (2013-08-20) - Vector diagram: Phase angle detection of L2 fixed for ZxD300/400 with firmware release B32. - IEC command: Extended test mode working with all measured quantities. - Reset meter data: working with ZxD300/400 with firmware release B32 and disabled dedicated event logs. Changes to release 4.7.18 (2013-06-24) - Communication settings: Access level 2 with static password has been added. - Profiles: Filling of incomplete profiles supported for all columns (not only missing time stamps). - Profiles: Filling of incomplete profiles supported in case of reversed sort order. - Profiles: Enhanced behaviour in case of access errors. - GSM installation tree: Names of telecom providers updated. - DIP table: Number of dips shown without decimal places. - Vector diagram: CT/VT ratio added for E650 with firmware B32. - Excel-Export: System error messages in case of failed Excel export fully shown. - Excel-Export: Excel profile export supported again using MS Office 2003. - Load profile analysis. Command removed. A graphical representation of a profile can be obtained based on the Excel export file of a profile. - New IEC command: Enhanced test mode with selection of measured quantity supported. - New devices and firmware releases: - ZxR100xC with firmware release K76 - ZxR100xR with firmware release K53 - ZMF100 with firmware releases M27 - ZCX100P with firmware release V43.01.02 - ZMX300P with firmware release V48.01.02 - ZMX300G with firmware releases V07.02.01 - ZMG300/400 with firmware release P07 - E230 und E350 series: Command to read and write the display and readout lists completely redesigned. The lists can be loaded and saved, additional parameters can be changed. - E450 series: New command added to read and write the in home display parameters. - E450 series: Disconnector command suppressed for devices without disconnector. - E450 series: The entry screen of the following E450 write commands can be scaled up and down: Time of Use, M-Bus Settings, In Home Display - E450 series: Enabling and disabling of the M-Bus registers adapted: The unit is always reset. - ZxQ200: Maximum primary voltage in case of primary data adaptation enhanced to 1200 kV. - ZxD300/400: New demand and power factor thresholds are immediately activated. - ZxD300/400: The demand monitor thresholds are shown correctly independent of the regional settings of the PC. - ZxD300/400: Additional power quality registers added to billing values and instantaneous values readout (firmware B32 only). - ZxG300/400: Error corrections in the checks of the transmission speed of the electrical interface settings. - ZxG300/400: Power factor register in 10 highest maximum demands log shown correctly. - ZxR100: New command to modify the billing period reset settings supported. - ZxR100: New command to change the parameterisation ID supported. - ZxR100: New commands to reset various fraud detection events supported. - ZxR100xR: New visualisation of the TOU: Season and week tables have been combined. - ZxR100xR: 'Script' and 'script selector' entry removed from day tables in TOU control. - ZxR100xR: New command to reset the event log supported. - CU-Ex: TCP/IP settings can be changed without error message. Changes to release 4.6.10 (2013-02-08) - Operating systems: .NET framework release 4.5 supported (no table error message anymore when reading e.g. billing values). - Communication Settings: Length of phone numbers extended to 40 characters. - Command tree: Additional device specific dlms commands added to read the firmware version as well as the COSEM logical device name. - Readout of billing values and profiles: Enhancement of the decoding of event and status registers. - Readout of billing values: Negative power factors are shown. - Profiles: Cell format in case of Excel export is the same as in release 4.3 and earlier. - Profiles: Delay in the view of the profile selector removed. - IEC profile readout: Profiles containing only one column are shown correctly. - Parameterisation ID: Value range extended in the IEC write command. - Firmware update E450 and CU: Command to activate a new firmware doesn't create an error message anymore. - New devices and firmware releases: - ZxD300/400 with firmware release B32 - CU-P4x: Changes to be in line with most recent D71 firmware. - CU-P4x: Invalid field strength values shown correctly in GSM installation tree. - ZMF100/ZCF100: Command to read and write the IEC device address added (restricted character set according to standard). - ZMF100/ZCF100: Register resolution 5.2 in test mode supported again. - ZMF100/ZCF100: Content of display and readout lists adjusted (unsupported entries removed). - ZxR100xC/xR: Duplicate entry for stored values removed from display and readout lists. - ZxR100xR: Naming of week days changed in the time of use. - ZCX100P/ZMX300P: Device ID 6 readable (firmware releases V48.01.01 and V43.01.01 only). Changes to release 4.5.10 (2012-10-02) - Command tree: Structure of 'all dlms commands' and 'all IEC commands' modified: Additional separation between generic commands working with all devices and device specific commands. The generic commands also work with new, not yet supported Landis+Gyr devices or even with 3rd party devices of other manufacturers. - Profiles: Time base for readout has been added for devices supporting this feature. - IEC Readout Event Log: Decoding of header is correct. - Clock: If it is not possible to set the clock due to insufficient access rights an error message is returned. - Vector diagram: Angles U3-I3 > 120° supported. - New devices and firmware releases: - ZCX100P with firmware release V43.01.01 - ZMX300P with firmware release V48.01.01 - ZMX300G with firmware releases V07.02.00, V07.01.05 - ZMF100 with firmware releases M26 - ZCF100 with firmware releases M55 - Firmware update E450: Checksum calculation fixed, image files can be created again. - AD-xE: TCP/IP settings of the module can be changed. - ZMF100/ZCF100: 1 new command with selection possibility to set the register resolutions replacing the 11 currently used commands. - ZxR100xC/xR: Register resolution can be adapted. - ZxR100xR: Last configuration change ID can be adapted. - ZxR100xR: Time of use table download supported. - E450 series: Utility serial number 2 of M-Bus devices is shortened correctly. Changes to release 4.4.12 (2012-07-03) - License: User names with more than 16 characters can be further used. - TOU tables: Season tables are visible and editable again. Changes to release 4.4.08 (2012-06-15) - Tool: New high resolution tool icon. - License: The license is handled individually per Windows user and per main .MAP110 release on a single PC. Up to the same license was valid for all Windows users and all .MAP110 releases of the same PC. Any license change or a new license only affects the current Windows user as well as the current release of .MAP110. In case of a .MAP110 upgrade the current license is kept, i.e. it is copied once to all users of the PC. The license policy has not changed, i.e. all existing license keys can be further used and shared between different users of a PC. - Communication: The reading of a profile using the IEC R6 command is not interrupted anymore after receiving as block check character. - Communication: All formatted IEC commands can be sent to a CU if the logical device is set accordingly in the communication settings. - New devices and firmware releases: CU-P4 with firmware release D71. - Firmware update: CU-P4 supported. - Firmware update: Firmware can be transferred to a device, but activated later with a new command. - Communication settings CU: Command sequence rearranged so that only differences will be written and not always all parameters (similar as in MAP120). - CU-Px/Gx: Time window of modem is shown again. - AD-xP: PLC settings extended and supported for all firmware releases. - ZxR100xC/xR: The settings of the optical and electrical interfaces can be adapted. - ZxR100xC/xR: The settings of the pulse output can be adapted. - ZxR100xC/xR: All display and readout lists can be adapted. - ZMF100/ZCF100: The settings of the optical and electrical interfaces can be adapted (firmware M23..M25 and M52..M54 only). - ZMF100/ZCF100: The settings of the pulse output can be adapted (firmware M23..M25 and M52..M54 only). - ZxD300/400: Reparameterisation of the billing period reset table corrected in various cases. Changes to release 4.3.08 (2012-03-15) - Additional licenses available according to license overview. - Communication settings: Several new icons in toolbars. - Communication settings: Layout of communication interface selection and template handling improved. - Communication settings: Access level 7 has been extended and supports all 3 password variants (no/static/coded password). - Communication settings: The migration order of former communication settings has been modified: The current communication settings directory is browsed first for any former version before switching to the default directory.- Communication Settings - Communication: Enhanced progress bar while executing a command. - Communication: Dlms link layer can be used without repetitions again. - File open: Commands to open previously stored files are located in the corresponding window and not in the file menu anymore. - Billing values readout: Some status words are encoded using a tool tip (same behaviour as in profiles). - Billing values readout: All identification numbers of the time of use tables are shown with OBIS code 1-0:0.2.2 and 1-0:0.2.7. - Read diagnostic values: All time stamps have been extended with the clock status. - Read clock: Command has been extended with the clock status and a new layout. - Profiles: Enhanced export function to Excel and several other modifications: Opening of stored profiles supported again, some missing units added. - ID numbers: Commands to read and write the identification number 2 renamed according to OBIS standard (Device ID). - Vector diagram: Printout corrected when using Windows XP. - New devices and firmware releases: - ZMF100 with firmware releases M25 - ZCF100 with firmware releases M54 - ZxR100xC with firmware release K75 (formatted IEC commands only) - ZxR100xR with firmware release K52 (formatted IEC commands only) - ZMX300G with firmware release V07.01.04, V07.01.03 - New commands: In conjunction with the new devices also some new commands have been added. They are only available for these new devices. - ZxG300/400: Changes of the communication settings for master-slave operation mode fixed (firmware P06 only) Changes to release 4.2.20 (2011-12-16) - Operating systems: PC's with Turkish language settings supported again. - Load profile analysis supported again. - Set clock: The status is masked with 'FF' instead of '00' (the same as in 'Set clock to PC time'). - New devices and firmware releases: Communication module AD-xP/xG with firmware release T05 und T25. - AD-xE: Billing values readout corrected and enhanced. - ZxD100AR: Control status register '96.3.x', '96.4.x' and '96.5.0' in billing values readout added again. - ZxD300/400: Control status register '96.3.x', '96.4.x' and '96.5.0' in billing values readout added again. Changes to release 4.2.18 (2011-11-14) - Operating systems: .NET framework release 4.0 required. - Tool: Multiple instances of .MAP110 can be started in parallel. - Communication: The communication settings and toolbars have been further enhanced and adapted (version 8). - Communication: Direct access to the current communication settings from the toolbar. - Communication: Introduction of a virtual device named 'any device', which is automatically linked to all communication channels. - Communication: Default values for the settings of a communication channel can be loaded from an application specific template. - Communication: IEC and HDLC addresses can be individually selected again. - Communication: IPv6 supported. - Communication: Error handling in IEC protocol enhanced in case of access errors. - Billing values readout: Order, content and formatting of the billing data unified. - Billing values readout: OBIS codes 1-0:12.32.xx for voltage dip counters extended. - Profiles: Naming unified and selection possibilities reduced: Energy value profile => load profile 1, billing values profile => load profile 2. - Profiles: Slightly modified view due to the use of new technology. - Data export to Excel: Title of the export file according to the type of readout, e.g. load profile, billing values, etc. - Data export to Excel: If no Excel is installed, a corresponding error message is shown. - DIP table: Slightly modified view due to the use of new technology.. - Vector diagram: Slightly modified view due to the use of new technology.. - Vector diagram: If present primary values are also listed. - Vector diagram: All phase references supported (own phase or L1). - Read Clock: Date output corrected for devices using the Persian calendar. - Read Clock: Clock status added to readout. - ZxD300/400: Billing period reset table can be shortened correctly. - ZxG300/400: In case of modification of electrical interface 1, interface 2 is not touched anymore. - ZxF100: The character set of the identification numbers is restricted to: '0'..'9','-','_' and SPACE. - CU: dialogue boxes for the extended communication settings have been enlarged to allow a better representation on PC's using a magnified font. - CU-Px: IPT password can be written again. - AD-xP/xG: Configuration of M-Bus devices without disconnector written correctly. Changes to release 4.1.20 (2011-07-12) - Communication: After the establishment of a modem connection the correct phone number is shown in all cases. - ZxG300/400: GSM installation tree working again. - AD-xE: Reading of profiles enhanced.. Changes to release 4.1.18 (2011-06-15) - Tool: File saving to offline folders supported. - Tool: The user settings are saved in the local application data directory instead of the roaming directory (Windows 7 C:\Users\%current user%\AppData\Local\Landis+Gyr\.MAP110...). - Command Tree: After selection of a device the command tree is automatically switched if a device series has been assigned. - Command Tree: The logical device (base meter or communication unit) in the device settings is overridden by the selected command. It is no longer necessary to define two different devices for a meter and a communication unit located in the same place. - Communication: The communication settings and toolbars have been further enhanced and adapted (version 7). - Communication: Special characters again supported for device and communication channel names as well as address book entries. - Communication: Import of .MAP110 4.x address books supported. - Communication: IEC and HLDC addresses can be directly enabled and disabled in the device toolbar. - Communication: Either phone number or IP address toolbar shown depending on the interface type. - Communication: If the tool is minimised and maximised again, the currently selected access level is retained. - Communication: No default access level in communication channel settings anymore, i.e. the currently selected level remains untouched. - Communication: Gateway functionality adapted to latest green book draft (mainly address handling changed). - Communication: Transmission speed change in IEC protocol again supported for remote connections (e.g. modem or network). - Communication: IEC identification string shown correctly in all commands. - Communication: No data limit for IEC read commands in communication tracing anymore. - Communication: Default size of HDLC transmission buffer changed to 248 bytes. - Communication: Function modified to derive the hdlc address from the IEC address. - Communication: Addresses in toolbars sorted by name. - Communication: Cancellation of IP connection to an invalid destination supported. - Communication: Due to performance issues the colours had to be removed from the communication tracing window. - Communication: Direct use of HLDC protocol supported by Bluetooth optical heads. - Profile reading enhanced to support also large profiles. - New devices and firmware releases: - ZxG300/400 with firmware release P06 - Communication module AD-xE with firmware release V71.00 - ZMF100 with firmware release M24 - ZCF100 with firmware release M53 - Firmware update for E450 and E35C AD-xE devices supported. - AD-xP: New command to reset the PLC state to 'NEW' added. - AD-xP/xG: M-Bus device list extended by Landis+Gyr T550 and T230. - CU-Px: Changing of IP address mode via modem supported. - ZCF100: Write command 'Test Mode Energy Register Resolution 5.3' corrected. - ZCF100: Sending of display text message again supported. - ZCF100: Device filter modified to only show the supported commands. - ZxD300/400: Reset meter data supported for devices without extended power quality (firmware B31 only). - ZxQ200 - Primary data adaptation: The basic display unit of the primary reactive power is set to 'var' instead of 'W'. - ZxQ200 - Primary data adaptation: If necessary the display resolution of the primary instantaneous values (voltage, current, power) is adapted in accordance with the primary power. Changes to release 4.0.26 (2011-02-10) - Tool: File open possible even if the communication settings are invalid. - Communication: Communication interface detection enhanced and improved. - Communication: Error detection in case of interruption of the modem line improved. - Communication: Enhanced cancellation possibilities in case of long lasting communication operations. - Billing values readout: Scaling of registers corrected on PC's where "." has been selected as decimal symbol in the regional settings. - ZxF100: Changes in display and readout lists possible again (firmware release M21 only). - ZxD300/400: Reset meter data possible (firmware release B23 and B24 only). Changes to release 4.0.22 (2010-12-23) - Setup: The program is located in a dedicated Landis+Gyr program group in the start menu by default. - Operating systems: Windows 7 supported. - Tool: Modified GUI (toolbars, menus, windows). - Tool: Changing of user group moved to tool menu. - Command tree: New filters introduced based on device families. - Communication: Communication settings modified and enhanced. They are not only based on communication channels but additionally complete devices can be defined. - Communication: The location of the communication settings is user definable (in Tools\Options => File Locations). This allows the sharing of the communication profiles between different users of a PC. Please note that the existing files aren't moved nor copied if the directory changes. - Communication: Communication trace window included. - Communication: Landis+Gyr Bluetooth optical heads supported again. - Command log: After every successful communication the related device information (serial number, firmware version, type designation) is updated in status bar located in the bottom of the window. - OBIS codes: In all data readouts the OBIS code is shown in numeric format only (as defined in the standard) instead of partly using characters. Affected values: 'C'=96, 'F'=97, 'L='98' and 'P'=99. This allows a correct referencing to the standard. - Vector diagram: In the vector diagram the reading date as well as the meter serial number have been added. - Data export to MAP100: Export of data done in MAP100 version 2.0 format. - Data export to MAP100: If the option is activated, the icons of the affected commands are extended by a + sign. - Reset meter data: It is possible to set the clock, to reset all registers and profiles as well as to reset alerts and alarms (ZxD300/400, ZxG300/400 and ZxQ only). - New devices and firmware releases: - ZxD300/400 with firmware release B31 - ZxG300/400 with firmware release P05 - ZMF100 with firmware releases M22 and M23 - ZCF100 with firmware releases M51 and M52 - ZxH is not supported anymore - AD-xP/xG: M-Bus value selection not restricted anymore by medium in the M-Bus device configuration. - AD-xP/xG: DIF/VIF can always be entered for user defined M-Bus values. - AD-xG: Range of number of network login repetitions extended. - CU-Gx/Px: Handling of PIN code modified (has no effect on parameterisation). - CU-G3x/P3x: Support of BGS3 modem chipset. - ZxF100: Enhancement of display and readout lists with new measured quantities. - ZxF100: Unknown entries in display and readout lists are accepted. - ZxF100: Display and readout lists are written with correct length and activated immediately. - ZxG300/400: Inactive power factor monitors can't be written anymore. - ZxG300/400: When changing the integration period the instantaneous values used for the load profile are changed as well. - ZxD300/400: Inactive power factor monitors can't be written anymore. - ZxD300/400: Decoding of event status register corrected (firmware B30 only) - ZxQ200: Inactive power factor monitors can't be written anymore. - ZxQ200: List of possible resolutions of losses modified in case of primary power >320MW. - ZxQ200: In a profile readout the primary currents are shown correctly scaled. 3. System Requirements ---------------------- - Supported operating systems: - Microsoft Windows 10, Windows 8, Windows 7, Windows Vista. - Landis+Gyr .MAP110 may work on other MS Windows versions as well. These haven't been tested and there is no support available in case of problems. - The following system components which are not part of Landis+Gyr .MAP110 must be installed on your computer: - Microsoft .NET framework 4.6.1 or later - Microsoft Excel 2003 or later must be installed for extended analysis. 4. First Time Installation -------------------------- In order to install correctly Landis+Gyr .MAP110, a) ensure that you have administrator privileges on your computer b) start 'setup.exe' c) follow the instructions of the setup wizard 5. Upgrade ---------- 5.1 Upgrade of a former Landis+Gyr .MAP110 5.9 release to the most recent release 5.9 The newest release 5.9 automatically replaces any former release 5.9. All data including the license and the communication settings is kept. Start the installation procedure (start setup.exe) and confirm the upgrade. 5.2 Upgrade of Landis+Gyr .MAP110 5.8, 5.7, 5.6, 5.5, 5.4, 5.3, 5.2, 5.1, 5.0 and 4.x to the most recent release The new release can be installed in parallel to a former release. In this case a separate directory is required for the installation. It is strongly recommended to uninstall the old release because it will no longer be supported. All data including the license and the communication settings is kept. Procedure: 1. Uninstall old release 2. Install new release (start setup.exe) 3. In case of a parallel installation select a different directory 5.3 Upgrade of Landis+Gyr MAP110 3.x and earlier An upgrade of such a release is not supported, please perform a first time installation of the new release. 6. Supported Devices -------------------- E850 series - ZxQ200 with firmware releases H04, H03, H02, H01, H00 - ZMQ802 with firmware release H80 E650/S650 series - ZxD300/400 with firmware releases B40, B33, B32, B31, B30, B24, B23, B22, B21, B14, B11, B10 E570 series - ZxY400P with firmware release V81.02.02 - ZxY400G with firmware releases V82.03.03, V82.02.02 - ZxY400Q S2 with firmware releases V83.05.05*, V83.04.04* E550 series - ZxG300/400 with firmware releases P09, P08, P07, P06, P05, P04, P03, P02, P01 E460 series - MCA100 with firmware release V75.01.03, V75.01.02, V75.01.01* - MMA300 with firmware release V76.01.00 E450 series - ZCX100P with firmware releases V01.02.14, V01.02.13*, V01.02.11*, V01.02.10* - ZMX300P with firmware releases V09.00.01, V09.00.00, V03.02.14, V03.02.13*, V03.02.11*, V03.02.10* - ZMX300G with firmware releases V07.02.02, V07.02.01, V07.02.00, V07.01.05, V07.01.04, V07.01.03 - ZCXi100P S2 with firmware releases V43.05.00, V43.04.00, V43.01.02, V43.01.01 - ZMXi300P S2 with firmware releases V48.05.00, V48.04.00, V48.01.02, V48.01.01 - ZFXi300P S2 with firmware release V68.02.01 - ZMXi300P S3 with firmware release V65.04.00, V65.03.00*, V65.02.00 - ZCXi100Q S4 with firmware releases V91.11.11, V91.10.10, V91.06.03, V91.05.02, V91.04.01*, V91.00.00* - ZMXi300Q S4 with firmware releases V93.11.11, V93.10.10, V93.06.03, V93.05.02, V93.04.01*, V93.00.00* E350 series - ZCF100 with firmware releases M59, M57, M56*, M55, M54, M53, M52, M51, M50, M40 - ZMF100 with firmware releases M29, M28, M27, M26, M25, M24, M23, M22, M21, M14, M13, M12 E230 series - ZxR100xR with firmware releases K53, K52 - ZxR100xC with firmware releases K76, K75 E65C series - Communication units Ax/Bx/Mx/Gx/Dx/Ex/Px/Ux/Lx with firmware releases D81, D72, D71, D60, D51, D50, D45, D44, D43, D42 E35C series - Communication modules AD-xP with firmware releases T05, T04, T01, T00 - Communication modules AD-xG with firmware releases T25, T24, T23, T22, T21, T20 - Communication modules AD-xE with firmware release V71.00 - Communication modules AD-xU with firmware releases V54.10.10, V54.01.01, V54.01.00, V56.00.00 Other devices - ZxD100AP with firmware releases G03, G02 - ZxD100AR with firmware releases I06, I05, I04, I03, I02, I01 * = device not released in .MAP110 or device not yet released at all Other Landis+Gyr devices, other firmware releases or devices of other manufacturers may fully or partly work but haven't been tested. 7. Known Restrictions --------------------- - If you are using an UHD display and a display scale factor >100% the .MAP application changes its size to 100% as soon as a command is executed or when opening the about box. Use a link in which the 'Disable display scaling on high DPI settings' property is ticked in the compatibility settings to run .MAP110. - When using reading heads with USB connection it might happen that the program is blocked. In such cases either the USB device must be removed or the PC must be rebooted. If the problem persists it is strongly recommended to upgrade the affected USB driver. - The first startup of Landis+Gyr .MAP110 can take quite long (5-20 seconds) depending on the performance of your PC because the .net environment must be initialised first. - It is not possible to import former address book versions 'AddressBookVx.xml' using the 'Import address book' function. This applies to V7 and earlier. 8. Languages ------------ The tool is available in English and German. The language can be changed in the tool menu but requires to start up again the tool. Your Landis+Gyr representative will inform you on the availability of Landis+Gyr .MAP110 in your local language. 9. Licensing ------------- The software is not copy protected, everybody is allowed to install a demo release with limited functionality. To obtain a valid license please contact your local Landis+Gyr representative. The licensing requires administrator privileges on your computer. 10. Support ----------- In case of questions on .MAP tools or Landis+Gyr meters please contact your local Landis+Gyr representative. http://www.landisgyr.com